FLEX 3000

FLEX 3000

Flexible Current Transformers. The flexible current transformers FLEX 3000 ensure safe, accurate and non-intrusive measurements in applications that may be completely inaccessible with conventional current clamps and probes.

FLEX 3000 Technical Data

The flexible current transformers FLEX 3000 ensure safe, accurate and non-intrusive measurements in applications that may be completely inaccessible with conventional current clamps and probes.

The probes provide a linear voltage output that is an exact replica of the input waveform for three user selectable input current ranges of 30, 300 or 3000 Amperes. The standard 610 mm flexible conductor allows a measuring diameter of up to 194 mm.

Advantages

  • Ideal for large and hard-to-reach conductors
  • Flexible and lightweight, less than a quarter of the weight of conventional CTs
  • No restrictions with regard to duty cycle or overload current
  • Selectable current ranges of 30 / 300 / 3000 A
  • AC coupled mV output proportional to measured current
  • Accuracy: Ein + Em Ein: Accuracy of instrument input Em: Accuracy specified by manufacturer
  • Basic specifications for 45 Hz … 65 Hz: Accuracy: ±1 % of range Phase error: < ±1° Position sensitivity: ±2 % of reading

Download Product Datasheet

Parameter Specification
Probe and cable material Alcryn 2070 NC double insulated, UL94 V-0
Couplings material Ultramid A3U Q720, UL94 V-0
Probe length 610 mm
Conductor diameter 194 mm
Probe diameter Nominal 9.9 mm
Output connection 7-core cable / 2 m long Redel-plug
Operating temperature -20 °C … +80 °C
Storage temperature -40 °C … +90 °C
Operating humidity Non-condensing 15 % … 85 %
Degree of protection (probe) IP65
Degree of protection (integrator module) IP4X

Engage Our Engineering Team

Whether you’re establishing a new meter testing facility, upgrading existing infrastructure, improving measurement confidence, or addressing compliance requirements, Sable Logic provides practical engineering support backed by industry experience. Contact our team to discuss your operational and testing requirements.